GLOBAL BEST DAEKWANG
SIGLENT’s SDS2000X Plus series Digital Storage Oscilloscopes are available in bandwidths of 350 MHz, 200 MHz and 100 MHz, have a maximum sample rate of 2 GSa/s, maximum record length of 200 Mpts/ch, and up to 4 analog channels + 16 digital channels mixed signal analysis ability.
The SDS2000X Plus series employs SIGLENT’s SPO technology with a maximum waveform capture rate of up to 120,000 wfm/s (normal mode, up to 500,000 wfm/s in Sequence mode), 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports multiple powerful triggering modes including serial bus triggering. History waveform recording, Sequence acquisition, Search and Navigate functions allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 50 MHz waveform generator, as well as serial decoding, mask test, bode plot, and power analysis are also features of the SDS2000X Plus. A 10-bit acquisition mode helps to satisfy applications which require more than 8-bit resolution.
The large 10.1’’ capacitive touch screen supports multi-touch gestures, while the remote web control, mouse and external keyboard support greatly improve the operating efficiency of the SDS2000X Plus.
Key Features
◆ 350 MHz, 200 MHz, 100 MHz models with real-time sample rate up to 2 GSa/s. A 500 MHz bandwidth upgrade option is available for 350 MHz models.
◆ SPO technology
• Waveform capture rates up to 120,000 wfm/s (normal mode) and 500,000 wfm/s (sequence mode)
• Supports 256-level intensity grading and color temperature display modes
• Record length up to 200 Mpts/ch, 400 Mpts in total for all 4 channels
• Digital trigger system
◆ Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern and Video (HDTV supported). Trigger zone helps to simplify advanced triggering
◆ Serial bus triggering and decoder, supports IIC, SPI, UART, CAN, LIN (Standard) and CAN FD, FlexRay, IIC, and MIL-STD-1553B (optional) protocols
◆ Low background noise, supports 0.5 mV/div to 10 V/div voltage scales
◆ 10-bit mode provides higher resolution and lower noise
◆ Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 90,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
◆ History waveform record (History) function for up to 90,000 triggered waveforms (frames)
◆ Automatic measurement function on 50+ parameters, supports statistics with histogram and trend
◆ Two Math traces, support 2 Mpts FFT, +, -, x, ÷, d/dt, ∫dt, √, average, ERES, and formula editor
◆ Abundant data processing and analysis functions such as Search, Navigate, Mask Test, Bode plot, Power Analysis (optional) and Counter
◆ 16 digital channels (optional)
◆ Built-in 50 MHz waveform generator (optional)
◆ Large 10.1” TFT-LCD display with 1024×600 resolution; Capacitive touch screen supports multi-touch gestures
◆ Multiple interfaces: USB Host, USB Device (USBTMC), LAN(VXI-11/Telnet/Socket), Pass/Fail, Trigger Out
◆ Supports SCPI remote control commands
◆ Supports Multi-language display and embedded online Help
Characteristics
![]() Up to 120,000 wfm/s waveform update rate |
Edge, Slope, Pulse, Video, Windows, Runt, Interval, Dropout, Pattern and serial trigger. |
Trigger Zone is available for advanced triggering.
Hardware accelerated FFT up to 2 Mpts. This provides high frequency resolution with fast refresh rate.
The FFT function also supports a variety of window functions so that it can adapt to different spectrum measurement needs.
Three modes (Normal, Average and Max hold) can satisfy different requirements for observing the power spectrum.
Auto peak detection and markers are supported.
History function records up to 90,000 triggered waveforms (frames). This is done continuously in the background,
so the history waveforms can be played back at any time to find and analyze past events. Serial decode,
zoom and cursors measurements can be used.
Segmented memory collection will store the waveform into multiple memory segments (up to 90,000) and each segment will store
a triggered waveform together with the dead time information. The interval between segments can be as small as 2 µs.
All segments can be played back at an arbitrary framerate using the History function.
The SDS2000X Plus can find events within a record and history based on user specified trigger conditions.
Navigate browses through Events flagged by the Search, plays back history frames or continuously moves the delay position on
long records (useful in zoom view).
In addition to the decoder lanes correlated to the waveform, bus protocol information can be displayed in tabular form.
IIC, SPI, UART, CAN, LIN, CAN FD, FlexRay, IIS and MIL-STD-1553B are supported.
Complete Connectivity |
![]() USB Host, USB Device (USBTMC), LAN (VXI-11/Telnet/Socket), Auxiliary Output (Pass/Fail, Trigger Out) |
Ordering Information
Mode | Description |
SDS2102X Plus | 100 MHz, 2-ch, 2 GSa/s (Max,) , 200 Mpts, 10.1" touch screen |
SDS2104X Plus | 100 MHz, 4-ch, 2 GSa/s (Max,) , 200 Mpts, 10.1" touch screen |
SDS2204X Plus | 200 MHz, 4-ch, 2 GSa/s (Max,) , 200 Mpts, 10.1" touch screen |
SDS2354X Plus | 350 MHz, 4-ch, 2 GSa/s (Max,) , 200 Mpts, 10.1" touch screen |
Standard Accessories | |
USB cable x1 | |
Quick start x1 | |
Passive probe x2 (2-ch model); x4 (4-ch model) | |
Certificate of calibration x1 | |
Power cord x1 | |
Optional Accessories | |
SDS-2000XP-4BW02 | 100 MHz to 200 MHz bandwidth upgrade (4-ch model) (software) |
SDS-2000XP-4BW03 | 200 MHz to 350 MHz bandwidth upgrade (4-ch model) (software) |
SDS-2000XP-4BW05 | 350 MHz to 500 MHz bandwidth upgrade (4-ch model) (software) |
SDS-2000XP-2BW03 | 100 MHz to 350 MHz bandwidth upgrade (2-ch model) (software) |
SDS-2000XP-FG | Waveform generator option (software) |
SDS-2000XP-16LA | 16 digital channels (software) |
SPL2016 | 16-channel logic probe |
SDS2000XP-I2S | PS trigger & decode (software) |
ISFE | ISFE isolated front end |
SDS-2000XP-CANFD | CAN FD trigger & decode (software) |
SDS-2000XP-FlexRay | FlexRay trigger & decode (software) |
SDS-2000XP-1553B | MIL-STD-1553B trigger & decode (software) |
STB3 | STB3 demo signal source |
BAG-S2 | BAG |
HPB4010 | High voltage probe |
CPL5100/ CP4020/ CP4050/ CP4070/ CP4070A/ CP5030/ CP5030A/ CP5150/ CP5500 | Current probe |
DPB1300/ DP4080/ DPB5150/ DPB5150A/ DPB5700/DPB5700A | High voltage differential probe |
SDS-2000XP-PA | Power Analysis (software) |
DF2001A | Power Analysis deskew fixture |
※ 자세한 사항은 'DataSheet'나 'Manual'를 참조해 주세요.
품명 및 모델명 | 상품상세 참조 | 제조국 또는 원산지 | 상품상세 참조 |
---|---|---|---|
제조자, 수입품의 경우 수입자를 함께 표기 | 상품상세 참조 | A/S 책임자와 전화번호 또는 소비자상담 관련 전화번호 | 상품상세 참조 |
법에 의한 인증·허가 등을 받았음을 확인할 수 있는 경우 그에 대한 사항 | 상품상세 참조 |
- 배송비 : 기본배송료는 3,000원 (제주도 및 일부 도서산간 지역은 배송비가 추가됩니다.)
\200,000원 이상 구매시 무료배송
- 오후 5시 이전 주문시 통상적으로 당일 발송
- 제품 품절인 경우가 있기 때문에 납기일 확인 후 주문 부탁드립니다.
- 배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.
- 본 상품의 배송 가능일은 결제완료 된 날로부터 2~3 영업일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.
교환 & 반품안내
- 특수 제품, 주문 제품 등의 경우, 그 특성상 주문이 접수된 후 취소 및 환불이 불가합니다. 주문 전 충분히 상담하신 후 구매해 주세요.
(특수 제품이란, 보유제품이 아닌 주문 후 생산하며 출고하는 제품을 말합니다.)
- 제품 특성상 주문이 접수된 후 단순 변심에 의한 취소 및 환불은 당일에 한해 가능합니다. (취소및 환불 접수전 반드시 고객센터를 통해 연락바랍니다.)
- 전자 제품 특성상 제품포장 개봉 후에는 교환 및 환불이 불가능합니다. (제품 하자 제외)
- 모든 교환·반품은 수령 후 7일 이내 접수되어야 하며, 접수 전에 고객센터로 문의해 주셔야 진행이 가능합니다.
- 미개봉 제품의 경우, 받으신 날로부터 7일 이내 접수하시면 교환이 가능합니다.
- 개봉하신 제품은 7일 이내라도 교환이 불가합니다.(제품 하자 제외)
- 배송된 날로부터 7일이 지나면 어떤 교환·반품도 불가하므로 받으시면 제품 상태를 꼭 확인해 주세요. (제품 하자 포함)
- 소비자 변심에 의한 교환은 왕복 운임을 부담하셔야 합니다.
환불안내
- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.
- 주문 제품, 특수 제품의 경우 교환/반품이 불가합니다.
- 주문 전 충분한 상담을 하신 후, 신중히 구매해 주세요.
- 환불신청시 왕복 운송료를 부담하셔야 합니다.
AS안내
소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.
:: A/S 처리 문의 ::
전화 : 02) 2617-0787
E-MAIL : kdk@kdk.co.kr
⊙ A/S처리기간은 5일~4주 정도로, 제품에 따라 상이합니다.
⊙ 무상보증수리 : 제조사의 품질보증 기간에 따라 다릅니다. 무상보증 수리기간은 일반적으로 1년, 3년입니다.
무상보증수리를 위한 왕복 배송료는 대광계측기(주)에서 부담합니다.
단, 무상보증기간일지라도 소모품 교체나 소비자 과실일 경우 비용이 추가될 수 있습니다.
⊙ 유상수리 : 무상보증 기간이 지난 제품에 이상이 생겼을 경우에는 유상수리를 하셔야 합니다.
기본적으로, 수리를 위해 대광계측기(주)로 보내시는 배송료는 고객 부담, 받으시는 배송료는 대광계측기(주)에서 부담합니다.
타사에서 구입한 제품도 대광계측기(주)에서 수리 가능합니다.