GLOBAL BEST DAEWANG

고객의 가치창조와 고객의 지속성장을
위하여 우리는 최선을 다합니다.

HOME >상품상세화면
전자로드 SDL1030X
  • 전자로드 SDL1030X
  • 전자로드 SDL1030X
  • 전자로드 SDL1030X
신상품

전자로드 SDL1030X

공유
특징
200W ; DC150V/30A, 0.1mV/0.1mA
모델명
SDL1030X
브랜드
SIGLENT
원산지
CHINA
무상보증기간
3년
배송비
0원 / 주문시결제(선결제) 조건별배송 지역별추가배송비
방문 수령지 : 서울특별시 구로구 디지털로 288 (대륭포스트타워1차) 1404호
정가
1,895,080
판매가
1,705,600
쿠폰받기
상품코드
1000001639
전자로드 SDL1030X
0
총 상품금액
총 할인금액
총 합계금액

상품상세정보

 

 

SDL1000X/SDL1000X-E series Programmable DC Electronic Load has a 3.5 inch TFT-LCD display, a user-friendly interface and superb performance specifications. The SDL1020X/SDL1020X-E models feature an input range of 150 V/30 A 200 W while the SDL1030X/SDL1030X-E have an input range of 150 V/30 A 300 W. The SDL1000X series leads with measurement resolution of 0.1 mV/0.1 mA and the base SDL1000X-E series resolution is 1 mV/1 mA and adjustable current rise times from 0.001 A/μs~2.5 A/μs. For remote communication and control, the SDL series includes RS232/USB/LAN interface types. The SDL1000X series delivers stability over a wide range of applications and can meet all kinds of testing requirements. including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace. 



Key Features


SDL1020X/SDL1020X-E (Single channel ): DC 150 V/30 A, total power up to 200 W 

SDL1030X/SDL1030X-E (Single channel ): DC 150 V/30 A, total power up to 300 W 

4 static modes / Dynamic mode: CC/CV/CR/CP 

CC Dynamic mode: Continuous, pulsed, toggled 

CC Dynamic mode: 25 kHz, CP Dynamic mode: 12.5 kHz, CV Dynamic mode: 0.5 Hz 

Measuring speed of voltage and current: up to 500 kHz 

Adjustable current rise time range: 0.001 A/us~2.5 A/us 

Min. readback resolution: 0.1 mV, 0.1 mA 

Short-circuit, Battery test, CR-LED mode, and factory test functions 

4-wire SENSE compensation mode function 

List function supports editing as many as 100 steps 

Program function supports 50 groups of steps 

OCP, OVP, OPP, OTP and LRV protection 

External analog control 

Voltage, Current monitoring via 0-10 V 

3.5 inch TFT-LCD display, capable of displaying multiple parameters and statessimultaneously 

Built-in RS232/USB/LAN communication interface, USBGPIB module (optional) 

Waveform trend chart and easy-touse file storage and call functions 

Includes PC software: Supports SCPI, LabView driver



Characteristics 


Steady state operating mode

  

Dynamic test mode up to 25 kHz (CC)

The SDL features four operating modes to provide flexible test capabilities. In CC mode, the electronic load will sink a constant current, regardless of the voltage at its terminals. In CV mode, the electronic load will cause a constant voltage to appear at its terminals. In CR mode, the electronic load will behave as a fxed resistance value. As shown in the figure, the electronic load will linearly change the current according to the input voltage. In CP mode, the electronic load will cause a constant power to be dissipated in the load. 


The transient test allows switching between two different load values. A common application is to test the dynamic characteristics of a DC source or DUT (Device-Under- Test). The transient test function enables the load to periodically switch between two set levels (Level A and Level B). The highest frequency can be set to 25 kHz in CC mode. The highest frequency can be set to 12.5 kHz in CP modes. 







4-wire SENSE compensation mode function



In CC/CV/CR/CW mode, when a load is connected to a power supply, it will cause a large voltage drop on the connection lines between tested instrument and terminals of load. Using remote sense, you can measure the voltage at the DUTs input terminals, effectively removing the additional error due to the voltage drop in the connection wires. 

  






Simplfy complex sequencing using the list operation function

You can generate complex load sequences quickly using the list operation function. Here, you can edit the setpoints, dwell time, and slew rate for each step in the test. *Slew rate can only be edited in CC mode.





Program function 


Battery discharge function 

In program (auto-test) mode, you can generate a sequence of tests using different modes, mode parameters and durations. This function is useful for automatically executing a set of tests on a device then display whether the tests passed or failed. Test results are easily viewed by pressing the up and down buttons. The load provides 8 nonvolatile registers to save auto-test file for recall later. Each file contains 1-50 steps to set up. Auto-test function is especially useful in the designing battery charging circuitry. 


The SDL1000X can also provide insight into battery performance by analyzing the discharge characteristics of the DUT. The SDL features three stop conditions for the discharge test: Voltage, capacity or time. The discharge process is immediately terminated if the stop conditions are met. This provides more control over the test termination and an extra layer of safety during critical tests. Throughout the test process the battery voltage, discharge current, discharge time and discharged capability is displayed clearly on the LCD panel. 







CR-LED Mode


OCPT/OPPT Mode

The SDL1000X includes a CR-LED mode specifcally for LED driver testing. Basing on the traditional CR mode, CR-LED mode adds a diode breakover voltage setting. When the input voltage is above this set value, the DC load start to work. Thus, it can emulate the actual characteristics of an LED. 


Over-current protection (OCPT) mode prevents drawing too much current from the DUT. After the input voltage reaches the Von point, the DC load will start to draw a current from the source after a delay time. The current value will increase by a certain step size at regular intervals. Simultaneously, the DC load will compare the input voltage to the OCP voltage:If it is lower, then the present current value will be compared to see if it is in the current range you have set. Within the range, the OCP test will evaluate Pass or Fail. If it is outside of the set range, the DC load will to increase drawing current and compare the voltage again.






Overpower-protection (OPPT) mode: When the input voltage has reached the Von point, the load will draw power after a delay time. The power value will increase by a step size at regular intervals. Simultaneously, the DC load will judge whether the input voltage is lower than OPP voltage you have set, if it is, then the present current value will be compared to see if it is in the current range you have set. Within the range, the OPP test will Pass or Fail. If it is outside of the set power, the load will continue to increase the power draw within the cut-off current range and compare OPP voltage with the input. 




Voltage Rise/Fall speed test


Voltage threshold function

The electronic load is also equipped to directly measure voltage rise and fall times. It can calculate the time from one voltage to another without the need for additional measurement instrumentation. With an SDL1000X, you can save money and improve effciency. 


The SDL1000X can be set to turn on or off if the input voltage is at, above, or below a set value. By defning these thresholds, you control when the load is active. Which minimizes test time and increases safety. 







Waveform trend chart function


Save/Recall setting parameters

The electronic load includes a waveform display function and supports the following operations for the waveform: Pause, recording, and capturing the waveform. You can quickly observe the trends of parameter changes as they occur throughout the test. 


The load allows you to save different types of fles to the internal and external memories. You can recall and read them when necessary. 







External analog control


Multiple policy protection modes

The load allows the user to control current or voltage through external analog terminals (EXT PRG). Input a 0-10 V analog to adjust 0-100% rated voltage and current. It is very useful for those applications that need to change the input value with external signals. 


The SDL1000X series Programmable DC Electronic Load provides five protection types: OVP, OCP, OPP, OTP and LRV. When OVP/OCP/OPP/OTP/reverse voltage protection (LRV) occurs, the load will immediately turn off the input and stop sinking. Then, a prompt message is displayed.

 


Spec Comparison 


 Model

Min. readback resolution 

 Display

 Current Slew Rate

 Measuring speed

 CC Dynamic mode frequency

 Mode

 Input power

 Input current

 Input voltage

 SDL1020X

 0.1 mV, 0.1 mA

 3.5 inch TFT-LCD display

 0.001 A/us~2.5 A/us

 up to 500 kHz

 25 kHz

 CC/CV/CR/CP

 200 W

 30 A

 150 V

 SDL1020X-E

 1 mV, 1 mA

 3.5 inch TFT-LCD display

 0.001 A/us~2.5 A/us

 up to 500 kHz

 25 kHz

 CC/CV/CR/CP

 200 W

 30 A

 150 V

 SDL1030X

 0.1 mV, 0.1 mA

 3.5 inch TFT-LCD display

 0.001 A/us~2.5 A/us

 up to 500 kHz

 25 kHz

 CC/CV/CR/CP

 300 W

 30 A

 150 V

 SDL1030X-E

 1 mV, 1 mA

 3.5 inch TFT-LCD display

 0.001 A/us~2.5 A/us

 up to 500 kHz

 25 kHz

 CC/CV/CR/CP

 300 W

 30 A

 150 V

 


Lineup


 SDL1020X

 150 V/30 A 200 W Programmable DC Electronic Load 

 SDL1020X-E

 150 V/30 A 200 W Programmable DC Electronic Load

 SDL1030X

 150 V/30 A 300 W Programmable DC Electronic Load

 SDL1030X-E

 150 V/30 A 300 W Programmable DC Electronic Load



Ordering Information

​

Contents 

SDL1030X  Programmable DC Electronic Load

USB Cable

Quick Start Guide

Calibration Certifcate 

Power cord 

 

 

※ 자세한 사항은 'DataSheet'나 'Manual'을 참조해 주세요.  

 

 

상품필수 정보

품명 및 모델명 상품상세정보 참조 허가 관련 상품상세정보 참조
제조국 또는 원산지 상품상세정보 참조 제조자/수입자 상품상세정보 참조
A/S 관련 연락처 02-2617-0787

배송안내

  

- 배송비 : 기본배송료는 3,000원 (제주도 및 일부 도서산간 지역 추가 배송비) 

     200,000원 이상 구매시 무료배송

- 오후 3시 이전 주문시 당일 발송

- 본 상품의 평균 배송일은 2~3 영업일 (결제 완료 후) 

- 주문 제품 및 특수 제품의 경우 정확한 배송 시일을 별도로 안내해 드립니다.

- 배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.

- 본 상품의 배송 가능일은 결제완료 된 날로부터 2~3 영업일입니다. 배송 가능일이란 본 상품을 주문하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.

 

 

교환 & 반품안내

 

- 특수 제품, 주문 제품 등의 경우, 그 특성상 주문이 접수된 후 취소 및 환불이 불가합니다. 주문 전 충분히 상담하신 후 구매해 주세요. 

- 제품 특성상 주문이 접수된 후 단순 변심에 의한 취소 및 환불은 당일에 한해 가능합니다. (취소 및 환불시 당사 고객센터로 먼저 연락 바랍니다.)

- 전자 제품 특성상 제품포장 개봉 후에는 교환 및 환불이 불가능합니다. (제품 하자 제외) 

- 모든 교환·반품은 수령 후 7일 이내 접수되어야 하며, 접수 전에 고객센터로 문의해 주셔야 진행이 가능합니다. 

- 미개봉 제품의 경우, 받으신 날로부터 7일 이내 접수하시면 교환이 가능합니다.

- 개봉하신 제품은 7일 이내라도 교환이 불가합니다.(제품 하자 제외)

- 배송된 날로부터 7일이 지나면 어떤 교환·반품도 불가하므로 받으시면 제품 상태를 꼭 확인해 주세요. (제품 하자 포함) 

- 소비자 변심에 의한 교환은 왕복 운임을 부담하셔야 합니다.

 

환불안내

 

- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.

- 주문 제품, 특수 제품의 경우 교환/반품이 어려울 수 있습니다.

- 주문 전 충분한 상담을 하신 후, 신중히 구매해 주세요.

 

AS안내

 

소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.

 

:: A/S 처리 문의 ::

전화 : 02) 2617-0787

E-MAIL : kdk@kdk.co.kr

 

⊙ A/S처리기간은 5일~4주 정도로, 제품에 따라 상이합니다. 

  

⊙ 무상보증수리 : 제조사의 품질보증 기간에 따라 다릅니다. 무상보증 수리기간은 일반적으로 1년, 3년입니다.

    무상보증수리를 위한 왕복 배송료는 대광계측기(주)에서 부담합니다.

    단, 무상보증기간일지라도 소모품 교체나 소비자 과실일 경우 비용이 추가될 수 있습니다.

     

⊙ 유상수리 : 무상보증 기간이 지난 제품에 이상이 생겼을 경우에는 유상수리를 하셔야 합니다.

       기본적으로, 수리를 위해 대광계측기(주)로 보내시는 배송료는 고객 부담, 받으시는 배송료는 대광계측기(주)에서 부담합니다.

       타사에서 구입한 제품도 대광계측기(주)에서 수리 가능합니다. 

이미지 확대보기전자로드 SDL1030X

전자로드 SDL1030X
  • 전자로드 SDL1030X
  • 전자로드 SDL1030X
  • 전자로드 SDL1030X
닫기

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

닫기

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

찜 리스트 담기

상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?

상단으로 이동